Pdf file is about k257 scpi user is available in several types of edition. K257 scpi user manual, iphone 6 the ultimate iphone 6 user manual discover how to use. K257 Scpi User Manual.PDF - Are you searching for K257 Scpi User Manual Books? Now, you will be happy that at this time K257 Scpi User Manual PDF is. Download and read k257 scpi user manual k257 scpi user manual some people may be laughing when looking at you reading in your spare time some may be.
General 1-1 System Requirements Microsoft Windows 7 and Windows 8 Operating System USB2.0 Interface x1 1-2 Installation Install the software before you first connect CLE1040 via USB. Unzip (extract) the software package if you got an zipped file. Run 'Setup' from the CD drive or the unzipped folder. Connect CLE1040 with PC via USB and turn it on. Windows will automatically find and installs the driver. The CLE1040 is installed as 4x COM ports. Control is done by sending (or reading) IEEE compatible ANSI text to (and from) the COM ports.
When the driver is installed correctly, you will find it at Device Manager, under Ports(COM & LTP) as 4 of 'Variable ISI Channel'. Page 2 Software Operation Manual Rev. 5 Designating COM Port Number The COM Port number for CLE1040 is automatically assigned by the system. You can always designate your desired number at property setting of the driver. Start Device Manager and double click the 'Variable ISI Channel' under Ports(COM & LTP) Go to 'Port Setting' Tab and click 'Advanced'. Change the COM Port Number. Page 4 Software Operation Manual Rev.
2.5 6 1-3 Control from Other Operating System The operation under the operating system rather than MS Windows 7 and 8 is not guaranteed, however the following information is disclosed for user convenience. CLE1040 communicates with a remote host via USB interface.
Free Manuals Downloads
USBCDC Class is applied and handled as RS232C serial interface. CLE1040 constructs USB I/F without FTDI part, but it complies the standard USB Communications Device Class. The Communications Device Class is not OS dependent and other operation system such as Linux has drivers comply to it.
Page 5 Software Operation Manual Rev. GUI 2-1 Stat up Once installed, you can start GUI by clicking the icon, 'CLE1040'. 2-2 Control GUI is to set the amount of insertion loss by the percentage (%) value to the entire dynamic range of CLE1040. Please remember the different model of CLE1040 has different dynamic range. Specify the% value in the number box or by the slide bar, by the step of 0.1%. Page 6 Software Operation Manual Rev.
2.5 8 # Name Description 1 Channel Windows Each channel setting 2 Status Shows the status of the channel. Green: Running Yellow: Busy Red: Error 3 Setting Value Shows the percentage in its dynamic range 4 Value Gage Slide to change the setting value in percentage 5 Value window Enter the setting value in percentage 6 Preset Window Enter or select the number for one click setting Right Click for editing the number. 7 Individual Control check box Check this box for allowing individual operation. Simultaneous operation is always available with #8 section. 8 Value Window for Simultaneous Operation Enter value or slide the bar for setting the value in dynamic range for simultaneous operation Page 7 Software Operation Manual Rev.
Commands 3-1 Conformity With some unique command dedicated for CLE1040, most of the commands are conformity with IEEEStd488 2 and SCPI LF(0x0A) is always (and only) required at the end of the command. 3-2 Dedicated Commands ISI Value OUTPut:ISI:LEVEl Specifies the ISI (loss) amount in percentage of CLE1040 s dynamic range, (0.0%%). OUTP:ISI:LEVEl OUTP:ISI:LEVEl? Example Arguments OUTP:ISI:LEVEl 50.0 0.0 0.0 ISI Output OUTPut:ISI:STATe Sets ISI output On/OFF Page 8 Software Operation Manual Rev. 2.5 10 OUTP:ISI:STAT OUTP:ISI:STAT? Example OUTP:ISI:STAT ON Arguments ON or OFF ON or OFF Page 9 Software Operation Manual Rev.
2.5 11 3-3 IEEE Std488-2 Command LF(0x0A) is always (and only) required at the end of the command.CLS Clear Status - Clears up entire status.CLS.ESE Event Status Enable Specifies (or queries) the register bit value of Event Status Enable. Arguments 0 255 0 255.ESR? Event Status Register Queries and clears Standard Event Status Register (SESR). 0 255.IDN? ID Query Queries the device s ID code (example) ARTEK,CLE1040,1.00 Page 10 Software Operation Manual Rev. 2.5 12.OPC Operation Complete Returns 1 when all operations complete and sets OPC bit (bit0) at SESR register.PSC.RST Specifies whether it clears the registers for ESER and SRER at system boot. Arguments 0 Do not clear the register 1 Clears the register 0 or 1 Reset Halts all the process and initiate the device.RST.SRE Service Request Enable Specifies (or queries) the register value of Service Request Enable (SRER).SRE.SRE?
0 255 Page 11 Software Operation Manual Rev. Read Status Byte Queries the Read Status Byte Register. Upon this command, the bit6 of STB becomes MSS. 0 255.TRG Triger This product does not support this function. Selftest This product does not support this function.
0.WAI Wait Halts the followed command until the current command completes.WAI Page 12 Software Operation Manual Rev. 2.5 14 3-4 SCPI Command LF(0x0A) is always (and only) required at the end of the command. STATus:OPERation:EVENt Returns and clears the Operation Status Register value. 0: None 1: No ISI value specified STATus:OPERation:CONDition Returns and the Operation Status Register value (will not clear the register). 0: None 1: No ISI value specified STATus:OPERation:ENABle Sets and reads the value of the Operational Enable Register. STAT:OPER:ENAB STAT:OPER:ENAB?
Arguments 1: Reflects variation of bit1 to bit 7 0: Invalidates the bit 0 variation 0 or 1 Page 13 Software Operation Manual Rev. 2.5 15 STATus:OPERation:EVENt Reads and clears the Questionable Status Register. STAT: QUES:EVEN? 0: no information bit0: emergency halt bit 1: time out When this bit is 1, a serious hardware error is suspected. The value is cleared once read, however, it will be set to 1 upon certain time period if the error is not resolved.
STATus:QUEStionable:CONDition Reads Questionable Status Register. STAT: QUES:COND 0: no information bit0: emergency halt bit 1: time out STATus:QUEStionable:ENABle Sets Questionable Status Register. STAT:QUES:ENAB STAT:QUES:ENAB?
Arguments 0 3: When each bit is 1, it reflects the variation to SBR register bit 3. 0 3 Page 14 Software Operation Manual Rev. 2.5 16 STATus:PRESet Initializes the Status register including Operation and Questionable status registers. STAT:PRES SYSTem:ERRor:NEXT?
Returns the oldest error information and clears the error.200,'Execution error' SYSTem:REMote Sets this device REMOTE mode. SYST:REM SYSTem:VERSion?
Returns SCPIversion '1990.0' Page 15 Software Operation Manual Rev. 2.5 17 3-5 Tips: Initial Status 1) Issue 'SYStem:REMote' command to start remote control 2) Difference between Start up and.RST When System Start up ISI Value: as the front panel dial specifies When.RST executed ISI Value becomes 0 3) No Trigger supported 4) Multiple commands can be received up to 127 letters 1.
While executing a certain command, only one command (a set of commands) is accepted for next execution. Commands after that are just ignored without any warnings.
When you send a command, make sure you get a response. If no response, repeat it until you get a response. Then, go to the next command.
Command Example.RST;.OPC? SYST:REM Initializes the output setting. Returns 1 once done.
Sets the system in remote mode. OUTPUT:ISI:LEVE 80;.OPC? Sets the ISI value to 80%. Returns 1 once done.
Wait for the response and issue the next command. No response is returned when error. When error, make appropriate actions. 2013 pharmacy sig study guide answers. From experiential data, it will not take more than 3 seconds to change the entire dynamic range (from 0% to 100%). You may process error action when you do not get the response for 5 seconds.
Page 16 Software Operation Manual Rev. 2.5 18 4 ERROR CODE,'No error' 100,'Command error' 103, 'Invalid separator' 108, 'Parameter not allowed' 110, 'Command header error' 113, 'Undefined header' 200,'Execution error' 201,'Invalid while in local' 220, 'Parameter error' 222, 'Data out of range' 310, 'System error' 311, 'Memory error' 350,'Queue overflow' 500,'Power ON' 800,'Operation complete' Page 17 Software Operation Manual Rev. 2.5 19 Customer Support Please contact with our customer support center. Worldwide Sales & Support Developed By Page 18 Software Operation Manual Rev.